Regulations for Exterior Building Maintenance in California

Regulations for Exterior Building Maintenance in California

Property Managers are responsible for the upkeep of building(s). This includes window washing, exterior painting, resealing/waterproofing. In California these services are regulated by Cal OSHA because of the risks involved with working at height and hazards to contractors, building occupants, and passersby. 

Navigating government regulations can be challenging due to technological innovations and the complexity and specificity of Cal OSHA Article 5 [1]. For your convenience, we have provided some guidance to common questions from property managers.

Do I Need Roof Equipment To Be Compliant With Cal OSHA?

Roof equipment is referred to as BMUs, monorails, carriages, swing stages, suspended scaffolding, outriggers, davits, and tie-back anchors. 

A common question asked by our clients in property management involves whether or not their building needs roof equipment for exterior building maintenance. Per Cal OSHA, Roof equipment is needed for window washing when the building has glass over 36 feet tall with some exceptions.

CalOSHA Article 5 allows buildings up to 48 feet that can be cleaned  by ground-based methods. For example, water-fed poles can be used to effectively reach windows for buildings up to 48 feet. 

It should be noted that Article 5 & 6 don’t require roof equipment to be used for construction work.

Steps For Getting Roof Equipment Installed:

There is a 4 step process to install roof equipment so it is in compliance with CalOSHA.

  1. An engineer licensed in Scaffold Inspections or Testing must design the equipment and deliver design documents
  2. Roof Equipment is then installed by licensed engineer
  3. Certification is performed annually by SIT Company.
  4. Roof guardrails are installed for worker safety

Requirements To Keep Roof Equipment Up To Code:

If your building has roof equipment there are 3 kinds of inspections to be familiar with.

Load Testing:

This involves an SIT company testing how much load the roof anchors can hold. 

Roof Equipment Certification:

This is a 4 step process performed annually where an SIT company ensures the safety and code compliance of all rooftop facade access or roof equipment. 

  1. Drawings of anchor installation
  2. Load testing report (within last 10 years)
  3. Passed visual inspection
  4. Creation of OPOS

If there is an existing platform on the roof, it has to be certified in order to have the entire system certified. The building can not just certify roof anchors and use a contractors platform.

Pre use Inspection:

A 30-Day Pre Use inspection must be completed on buildings with PI’s (Permanent Installation) or a BMU (Building Maintenance Unit), prior to maintenance.

What is an OPOS (Operating Procedures Outline Sheet)?

An OPOS establishes safe window cleaning practices for buildings. This document is created by a Cal OSHA licensed SIT (Scaffold Inspection & Testing) company. The document is a visual aid for window cleaning contractors and should be posted on the roof for all to see. An OPOS illustrates the safe usage, cleaning procedure, and setup of window washing equipment.

Do I Need An OPOS For Window Cleaning?

Cal-OSHA requires that all buildings over 36 feet in height provide an OPOS if the building uses a counter weight system, controlled descent apparatus, or has extreme architectural features which require the use of complex rigging or equipment for exterior window cleaning.

References:

  1. Department of Industrial Relations. Safety Order. Article 5. Window Cleaning